20 KVA Online UPS with Batteries
- Rs. 1484999.00
- Rs. 1484999.00
|
System parameter |
Rating |
20KVA/20kw (3in-1out) |
|
|
Technology |
IGBT based Double conversion PWM based online UPS |
| |
|
Parallel mode |
4 (N+1) |
| |
|
Installation mode |
Tower |
| |
|
|
Minimum Guaranteed Battery Backup time (Minutes) on Full Load |
60 minutes |
|
|
Input |
Rated voltage |
400VAC 3-phase,4-wire |
|
|
Voltage Range |
Three phase 175VAC -498VAC |
| |
|
Rated Frequency |
50Hz/60Hz |
| |
|
Frequency Range |
40Hz~70Hz |
| |
|
Input phase reversal correction |
Inbuilt |
| |
|
Power factor |
0.95 for Three Phase |
| |
|
Output |
Rated power |
20KVA/20kw |
|
|
Voltage |
Single Phase 230/220 Vac. |
| |
|
Frequency synchronization range |
Rated frequency±3Hz. Configurable range: ±0.5Hz ~ +5Hz |
| |
|
Rated Power Factor |
Unity |
| |
|
Crest Factor |
3:1' |
| |
|
Voltage harmonic distortion |
< 2% (linear load) |
| |
|
Voltage Regulation |
1% |
| |
|
Dynamic response recovery time |
60ms |
| |
|
Inverter Overload Capability on utility mode |
At 25°C: 105%~ 125%- 5min; 125% ~ 150% 1min; 150%- more than 200ms |
| |
|
Inverter Overload Capability on battery mode |
At 25°C :105%~125%-60~30 s; >125%- more than 200ms |
| |
|
|
Isolation transformer |
Inbuilt at o/p side |
|
|
Bypass |
Separate bypass |
Yes |
|
|
Maintenance bypass |
Inbuilt |
| |
|
Static bypass |
Inbuilt |
| |
|
Efficiency |
ECO Mode |
96% |
|
|
Online mode (AC-AC) |
>91% |
| |
|
Inverter Efficiency (DC-AC) |
>88% |
| |
|
Transfer Time |
Mains - Battery |
Synchronous transfer: ≤0ms |
|
|
Inverter-Bypass |
Asynchronous transfer (default): ≤20ms |
| |
|
Noise |
<65db |
| |
|
Panel display mode |
Display typе |
Graphical LCD display |
|
|
No of events stored |
Max 256 |
| |
|
Orientation |
Gravity sense |
| |
|
Environmental |
Operating temperature |
0°C~50°C(2) |
|
|
Storage temperature |
a. -40°C~ +70°C (battery excluded); -25°C~ +55°C (battery included) |
| |
|
Relative humidity |
5%RH~95%RH, non-condensing |
| |
|
Altitude |
≤3000m; derating when higher than 3000m |
| |
|
Mechanical |
W*D*H (mm) |
550 X 620 X 700 |
|
|
Weight (Kg) |
158 |
| |
|
Ventilation |
Forced -air cooled |
| |
|
Ingress protection level |
IP20 |
| |
|
colour |
Powder coated Black Texture finish |
| |
|
Cable entry |
Rear |
| |
|
Network |
Smart RS232/USB |
Supports Windows 2000/2003 /XP/Vista/2008, Windows 7, |
|
|
SNMP |
Inbuilt for web monitoring |
| |
|
MODBUS |
Inbuilt for BMS connectivity |
| |
|
Remote alarm |
Inbuilt |
| |
|
Optional SNMP |
Power management from SNMP manager and web browser |
| |
|
Management software |
Site monitor |
| |
|
Modbus |
Inbuilt via multifunction port |
| |
|
Certifications |
Safety (CE) |
IEC/EN62040-1-1 |
|
|
Electromagnetic Compatibility (EMC) |
IEC/EN62040-2, IEC/EN61000-3-11, |
| |
|
Surge Protection |
IEC/EN62040-2, meeting IEC/EN61000-4-5 |
| |
|
Energy star |
As per UL approved |
| |
|
ROHS |
Yes |
| |
|
NABL Approved government lab test report. |
Available |
| |
|
OEM must be ranked in top |
Yes |
| |
|
Quality standard |
ISO 9001-2015 |
| |
|
Environment standard |
ISO 14001 |
| |
|
OSHAS |
ISO 45001 |
| |
|
IT security management |
ISO 27001 |
| |
|
Warranty |
UPS |
3 Years |
|
|
Batteries for UPS | |||
|
Battery |
Type |
Sealed, lead-acid, Tubular, LI-ION |
|
|
No's of Batteries |
36 units of 42 Ah 12V SMF VRLA Batteries for 30 min back up. |
| |
|
Battery charging capacity |
13A |
| |
|
|
Warranty |
2 Years |
|
-